| 1 | BASS communication time monitoring | 
    | 2 | USS communication time monitoring | 
    | 3 | Cyclic data time monitoring | 
    | 4 | Demand data time monitoring | 
    | 5 | Incompatible software | 
    | 6 | Invalid boot source entry | 
    | 7 | Program branching error | 
    | 8 | Drive blocked | 
    | 9 | Incremental encoder 1, scaling error | 
    | 10 | EEPROM-to RAM copy error | 
    | 11 | Damaged boot data record header | 
    | 12 | Boot data record checksum error | 
    | 13 | Damaged primary data header | 
    | 14 | EEPROM too small | 
    | 15 | Error on data record save | 
    | 16 | Ambiguous converter type BKD/BKF (1-Q/4-Q) | 
    | 17 | Error ext. analog - digital converter | 
    | 18 | Unknown field power unit identifier | 
    | 19 | Field connection error (AC) | 
    | 20 | Armature power unit connection error (AC) | 
    | 21 | CCW rotating field at armature power unit | 
    | 22 | Phase failure at armature power unit | 
    | 23 | Microprocessor error 1 | 
    | 24 | Microprocessor error 2 | 
    | 25 | Microprocessor error 3 | 
    | 26 | Microprocessor error 4 | 
    | 27 | Microprocessor error 5 | 
    | 28 | Microprocessor error 6 | 
    | 29 | Microprocessor error 7 | 
    | 30 | External watchdog tripped | 
    | 31 | Internal watchdog tripped | 
    | 32 | RAM test error | 
    | 33 | Parameter conflict (P 071 / P 073) | 
    | 34 | Repeated negative actual armature current | 
    | 35 | No synchronisation | 
    | 36 | Firing pulse interval differs from specified value | 
    | 37 | Armature circuit open (a = aG and lA < 10 % of setpoint) | 
    | 38 | Mains frequency < 45 Hz | 
    | 39 | Mains frequency > 65 Hz | 
    | 40 | Field current monitoring (actual field current < 50 % field current setpoint) | 
    | 41 | P 072 out of range | 
    | 42 | P 213 / P 215 parameter conflict | 
    | 43 | Shortcircuit/overload at a digital output | 
    | 44 | Overspeed (n > P 501) | 
    | 45 | Tachogenerator/encoder failure or armature circuit open (time to trip 12 scan cycles / 40 ms at 50 Hz) | 
    | 46 | Tachogenerator/encoder polarity reversed (time to trip 12 scan cycles / 40 ms at 50 Hz) | 
    | 47 | Speed range error (P 257) | 
    | 48 | Torque change time exceeded (> 100 scans) | 
    | 49 | Unknown armature power unit identification (current) | 
    | 50 | Data record selection error (digital input functions 1-6) | 
    | 51 | Input current < 3.3 mA at 4 mA to 20 mA | 
    | 52 | Mains undervoltage P 010 < 0.8 x P 070 | 
    | 53 | Overcurrent TD1 (lA > 2x P 072) | 
    | 54 | Overcurrent TD2 (lA > 2x P 072) | 
    | 55 | Zero-current detector defective | 
    | 56 | Offset error armature current detector > 50 mV | 
    | 57 | Ambiguous data record change source | 
    | 58 | EEPROM empty | 
    | 59 | Parameter error in data record 1 (write error/value) | 
    | 60 | Parameter error in data record 2 (write error/value) | 
    | 61 | Parameter error in data record 3 (write error/value) | 
    | 62 | Parameter error in data record 4 (write error/value) | 
    | 63 | Parameter error in data record 5 (write error/value) | 
    | 64 | Parameter error in data record 6 (write error/value) | 
    | 65 | Error in ROM data record (no. 7) | 
    | 66 | Primary data parameter error | 
    | 67 | Armature power unit identification differs from EEPROM value | 
    | 68 | Data record change: Data record does not exist | 
    | 69 | Field power unit differs from EEPROM value | 
    | 70 | Option board does not respond | 
    | 71 | Illegal value in P 072 / P 074 in data record 1 | 
    | 72 | Illegal value in P 072 / P 074 in data record 2 | 
    | 73 | Illegal value in P 072 / P 074 in data record 3 | 
    | 74 | Illegal value in P 072 / P 074 in data record 4 | 
    | 75 | Illegal value in P 072 / P 074 in data record 5 | 
    | 76 | Illegal value in P 072 / P 074 in data record 6 | 
    | 77 | Illegal value in P 079 in data record 1 | 
    | 78 | Illegal value in P 079 in data record 2 | 
    | 79 | Illegal value in P 079 in data record 3 | 
    | 80 | Illegal value in P 079 in data record 4 | 
    | 81 | Illegal value in P 079 in data record 5 | 
    | 82 | Illegal value in P 079 in data record 6 | 
    | 83 | EEPROM write time exceeded | 
    | 84 | Primary data checksum error | 
    | 85 | Checksum error in data record 1 | 
    | 86 | Checksum error in data record 2 | 
    | 87 | Checksum error in data record 3 | 
    | 88 | Checksum error in data record 4 | 
    | 89 | Checksum error in data record 5 | 
    | 90 | Checksum error in data record 6 | 
    | 91 | Undefined field bus card status | 
    | 92 | Field bus error | 
    | 93 | Field bus setpoint/actual value configuration error | 
    | 94 | P 657 / P 658 parameter conflict | 
    | 95 | Motor reached switch off temperature channel 1 ( motor temperature > P543 ) | 
    | 96 | Motor reached switch off temperature channel 1 ( motor temperature > P546 ) | 
    | 97 | Disconnection of motor temperature sensor channel 1 (X8:1 and X8:2 board 3.0043) | 
    | 98 | Disconnection of motor temperature sensor channel 2 (X8:4 and X8:5 board 3.0043) | 
    | 99 | Short circuit of motor temperature sensor channel 1 (X8:1 and X8:2 board 3.0043) | 
    | 100 | Short circuit of motor temperature sensor channel 2 (X8:4 and X8:5 board 3.0043) | 
    | 101 | Cable break temperature sensor power unit | 
    | 102 | Short circuit temperature sensor power unit | 
    | 103 | Power unit limit temperature exceeded (P112 = 1) | 
    | 104 | Error reaction freely definable error (P730 ^ 0) |