Servis zařízení Baumüller
Zpět na stránku opravySeznam chyb
Chybový kód | Název |
---|---|
1 | BASS communication time monitoring |
2 | USS communication time monitoring |
3 | Cyclic data time monitoring |
4 | Demand data time monitoring |
5 | Incompatible software |
6 | Invalid boot source entry |
7 | Program branching error |
8 | Drive blocked |
9 | Incremental encoder 1, scaling error |
10 | EEPROM-to RAM copy error |
11 | Damaged boot data record header |
12 | Boot data record checksum error |
13 | Damaged primary data header |
14 | EEPROM too small |
15 | Error on data record save |
16 | Ambiguous converter type BKD/BKF (1-Q/4-Q) |
17 | Error ext. analog - digital converter |
18 | Unknown field power unit identifier |
19 | Field connection error (AC) |
20 | Armature power unit connection error (AC) |
21 | CCW rotating field at armature power unit |
22 | Phase failure at armature power unit |
23 | Microprocessor error 1 |
24 | Microprocessor error 2 |
25 | Microprocessor error 3 |
26 | Microprocessor error 4 |
27 | Microprocessor error 5 |
28 | Microprocessor error 6 |
29 | Microprocessor error 7 |
30 | External watchdog tripped |
31 | Internal watchdog tripped |
32 | RAM test error |
33 | Parameter conflict (P 071 / P 073) |
34 | Repeated negative actual armature current |
35 | No synchronisation |
36 | Firing pulse interval differs from specified value |
37 | Armature circuit open (a = aG and lA < 10 % of setpoint) |
38 | Mains frequency < 45 Hz |
39 | Mains frequency > 65 Hz |
40 | Field current monitoring (actual field current < 50 % field current setpoint) |
41 | P 072 out of range |
42 | P 213 / P 215 parameter conflict |
43 | Shortcircuit/overload at a digital output |
44 | Overspeed (n > P 501) |
45 | Tachogenerator/encoder failure or armature circuit open (time to trip 12 scan cycles / 40 ms at 50 Hz) |
46 | Tachogenerator/encoder polarity reversed (time to trip 12 scan cycles / 40 ms at 50 Hz) |
47 | Speed range error (P 257) |
48 | Torque change time exceeded (> 100 scans) |
49 | Unknown armature power unit identification (current) |
50 | Data record selection error (digital input functions 1-6) |
51 | Input current < 3.3 mA at 4 mA to 20 mA |
52 | Mains undervoltage P 010 < 0.8 x P 070 |
53 | Overcurrent TD1 (lA > 2x P 072) |
54 | Overcurrent TD2 (lA > 2x P 072) |
55 | Zero-current detector defective |
56 | Offset error armature current detector > 50 mV |
57 | Ambiguous data record change source |
58 | EEPROM empty |
59 | Parameter error in data record 1 (write error/value) |
60 | Parameter error in data record 2 (write error/value) |
61 | Parameter error in data record 3 (write error/value) |
62 | Parameter error in data record 4 (write error/value) |
63 | Parameter error in data record 5 (write error/value) |
64 | Parameter error in data record 6 (write error/value) |
65 | Error in ROM data record (no. 7) |
66 | Primary data parameter error |
67 | Armature power unit identification differs from EEPROM value |
68 | Data record change: Data record does not exist |
69 | Field power unit differs from EEPROM value |
70 | Option board does not respond |
71 | Illegal value in P 072 / P 074 in data record 1 |
72 | Illegal value in P 072 / P 074 in data record 2 |
73 | Illegal value in P 072 / P 074 in data record 3 |
74 | Illegal value in P 072 / P 074 in data record 4 |
75 | Illegal value in P 072 / P 074 in data record 5 |
76 | Illegal value in P 072 / P 074 in data record 6 |
77 | Illegal value in P 079 in data record 1 |
78 | Illegal value in P 079 in data record 2 |
79 | Illegal value in P 079 in data record 3 |
80 | Illegal value in P 079 in data record 4 |
81 | Illegal value in P 079 in data record 5 |
82 | Illegal value in P 079 in data record 6 |
83 | EEPROM write time exceeded |
84 | Primary data checksum error |
85 | Checksum error in data record 1 |
86 | Checksum error in data record 2 |
87 | Checksum error in data record 3 |
88 | Checksum error in data record 4 |
89 | Checksum error in data record 5 |
90 | Checksum error in data record 6 |
91 | Undefined field bus card status |
92 | Field bus error |
93 | Field bus setpoint/actual value configuration error |
94 | P 657 / P 658 parameter conflict |
95 | Motor reached switch off temperature channel 1 ( motor temperature > P543 ) |
96 | Motor reached switch off temperature channel 1 ( motor temperature > P546 ) |
97 | Disconnection of motor temperature sensor channel 1 (X8:1 and X8:2 board 3.0043) |
98 | Disconnection of motor temperature sensor channel 2 (X8:4 and X8:5 board 3.0043) |
99 | Short circuit of motor temperature sensor channel 1 (X8:1 and X8:2 board 3.0043) |
100 | Short circuit of motor temperature sensor channel 2 (X8:4 and X8:5 board 3.0043) |
101 | Cable break temperature sensor power unit |
102 | Short circuit temperature sensor power unit |
103 | Power unit limit temperature exceeded (P112 = 1) |
104 | Error reaction freely definable error (P730 ^ 0) |