| 1 |
BASS communication time monitoring |
| 2 |
USS communication time monitoring |
| 3 |
Cyclic data time monitoring |
| 4 |
Demand data time monitoring |
| 5 |
Incompatible software |
| 6 |
Invalid boot source entry |
| 7 |
Program branching error |
| 8 |
Drive blocked |
| 9 |
Incremental encoder 1, scaling error |
| 10 |
EEPROM-to RAM copy error |
| 11 |
Damaged boot data record header |
| 12 |
Boot data record checksum error |
| 13 |
Damaged primary data header |
| 14 |
EEPROM too small |
| 15 |
Error on data record save |
| 16 |
Ambiguous converter type BKD/BKF (1-Q/4-Q) |
| 17 |
Error ext. analog - digital converter |
| 18 |
Unknown field power unit identifier |
| 19 |
Field connection error (AC) |
| 20 |
Armature power unit connection error (AC) |
| 21 |
CCW rotating field at armature power unit |
| 22 |
Phase failure at armature power unit |
| 23 |
Microprocessor error 1 |
| 24 |
Microprocessor error 2 |
| 25 |
Microprocessor error 3 |
| 26 |
Microprocessor error 4 |
| 27 |
Microprocessor error 5 |
| 28 |
Microprocessor error 6 |
| 29 |
Microprocessor error 7 |
| 30 |
External watchdog tripped |
| 31 |
Internal watchdog tripped |
| 32 |
RAM test error |
| 33 |
Parameter conflict (P 071 / P 073) |
| 34 |
Repeated negative actual armature current |
| 35 |
No synchronisation |
| 36 |
Firing pulse interval differs from specified value |
| 37 |
Armature circuit open (a = aG and lA < 10 % of setpoint) |
| 38 |
Mains frequency < 45 Hz |
| 39 |
Mains frequency > 65 Hz |
| 40 |
Field current monitoring (actual field current < 50 % field current setpoint) |
| 41 |
P 072 out of range |
| 42 |
P 213 / P 215 parameter conflict |
| 43 |
Shortcircuit/overload at a digital output |
| 44 |
Overspeed (n > P 501) |
| 45 |
Tachogenerator/encoder failure or armature circuit open (time to trip 12 scan cycles / 40 ms at 50 Hz) |
| 46 |
Tachogenerator/encoder polarity reversed (time to trip 12 scan cycles / 40 ms at 50 Hz) |
| 47 |
Speed range error (P 257) |
| 48 |
Torque change time exceeded (> 100 scans) |
| 49 |
Unknown armature power unit identification (current) |
| 50 |
Data record selection error (digital input functions 1-6) |
| 51 |
Input current < 3.3 mA at 4 mA to 20 mA |
| 52 |
Mains undervoltage P 010 < 0.8 x P 070 |
| 53 |
Overcurrent TD1 (lA > 2x P 072) |
| 54 |
Overcurrent TD2 (lA > 2x P 072) |
| 55 |
Zero-current detector defective |
| 56 |
Offset error armature current detector > 50 mV |
| 57 |
Ambiguous data record change source |
| 58 |
EEPROM empty |
| 59 |
Parameter error in data record 1 (write error/value) |
| 60 |
Parameter error in data record 2 (write error/value) |
| 61 |
Parameter error in data record 3 (write error/value) |
| 62 |
Parameter error in data record 4 (write error/value) |
| 63 |
Parameter error in data record 5 (write error/value) |
| 64 |
Parameter error in data record 6 (write error/value) |
| 65 |
Error in ROM data record (no. 7) |
| 66 |
Primary data parameter error |
| 67 |
Armature power unit identification differs from EEPROM value |
| 68 |
Data record change: Data record does not exist |
| 69 |
Field power unit differs from EEPROM value |
| 70 |
Option board does not respond |
| 71 |
Illegal value in P 072 / P 074 in data record 1 |
| 72 |
Illegal value in P 072 / P 074 in data record 2 |
| 73 |
Illegal value in P 072 / P 074 in data record 3 |
| 74 |
Illegal value in P 072 / P 074 in data record 4 |
| 75 |
Illegal value in P 072 / P 074 in data record 5 |
| 76 |
Illegal value in P 072 / P 074 in data record 6 |
| 77 |
Illegal value in P 079 in data record 1 |
| 78 |
Illegal value in P 079 in data record 2 |
| 79 |
Illegal value in P 079 in data record 3 |
| 80 |
Illegal value in P 079 in data record 4 |
| 81 |
Illegal value in P 079 in data record 5 |
| 82 |
Illegal value in P 079 in data record 6 |
| 83 |
EEPROM write time exceeded |
| 84 |
Primary data checksum error |
| 85 |
Checksum error in data record 1 |
| 86 |
Checksum error in data record 2 |
| 87 |
Checksum error in data record 3 |
| 88 |
Checksum error in data record 4 |
| 89 |
Checksum error in data record 5 |
| 90 |
Checksum error in data record 6 |
| 91 |
Undefined field bus card status |
| 92 |
Field bus error |
| 93 |
Field bus setpoint/actual value configuration error |
| 94 |
P 657 / P 658 parameter conflict |
| 95 |
Motor reached switch off temperature channel 1 ( motor temperature > P543 ) |
| 96 |
Motor reached switch off temperature channel 1 ( motor temperature > P546 ) |
| 97 |
Disconnection of motor temperature sensor channel 1 (X8:1 and X8:2 board 3.0043) |
| 98 |
Disconnection of motor temperature sensor channel 2 (X8:4 and X8:5 board 3.0043) |
| 99 |
Short circuit of motor temperature sensor channel 1 (X8:1 and X8:2 board 3.0043) |
| 100 |
Short circuit of motor temperature sensor channel 2 (X8:4 and X8:5 board 3.0043) |
| 101 |
Cable break temperature sensor power unit |
| 102 |
Short circuit temperature sensor power unit |
| 103 |
Power unit limit temperature exceeded (P112 = 1) |
| 104 |
Error reaction freely definable error (P730 ^ 0) |